Reset Device (20h)
Reset Hardware (21h)
Reset Hardware Device (22h)
Receive Configuration (41h)
Receive One Program (42h)
Receive Ram Area (47h)2
Continuous Controller Calculations
If (CC_Value == 127) {
Parameter Value = PARAM_MAX
}
else {
Parameter Value = (CC_Value * PARAM_MAX)/128
}
CC_VALUE The value of the continuous controller. (0-127)
PARAM_MAX The maximum value of the parameter the continuous controller is
changing.
Data format for the GFX-1 Receive Configuration procedure
Please note that each internal ram byte (d7 - d0) is transmitted as 2 midi
bytes. The first midi byte is 0000000xb where x is d7. The second midi byte
is 0xxxxxxxb where x is d6 - d0. Refer to the Receive Configuration
procedure in the General Midi Implementation Manual for required header
information.
Ram Byte Number Quick Definition
1 - 5880 120 Program definitions
5881 Program number