Request Configuration (00h)
Request One Program (01h)
Receive Configuration (41h)
Receive One Program (42h)
Continuous Controller Calculations
Parameter Value = (CC_Value * 2 * (PARAM_MAX + 1))/256
CC_VALUE The value of the continuous controller. (0-127)
PARAM_MAX The maximum value of the parameter the continuous controller is
changing.
Data format for the MEQs Receive Configuration procedure
Please note that each internal ram byte (d7 - d0) is transmitted as 2 midi
bytes. The first midi byte is 0000000xb where x is d7. The second midi byte
is 0xxxxxxxb where x is d6 - d0. Refer to the Receive Configuration
procedure in the General Midi Implementation Manual for required header
information.
Ram Byte Number Quick Definition
1 Program number
2 - 5 Midi receive channel numbers
6 - 9 Midi bank masks
10 - 40 MEQ band links to continous controllers
41 - 44 MEQ level links to continous controllers
45 MEQ bypass link to continous controller
46 Power up lock enable for MEQ 28
47 - 3511 99 MEQ program definitions