E-8
English
8.1
 
  
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
  
Settings for heating circuit 2/3

 
Parallel shift of the set heating curve for heating circuit 2/3. By
pressing the arrow buttons once, the heating curve is shifted by
1°C upwards (hotter) or downwards (colder).
Indicator bar
  

Settings to lower the heating characteristic curve of heating circuit
2/3
  


Sets the time during which the temperature in heating circuit 2/3 is
to be lowered.
00:00
to
23:59
  
 
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be lowered when the temperature
is lowered
0K
to
19K
  
  
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
  

All settings to raise the heating characteristic curve of heating
circuit 2/3
 


Sets the time during which the temperature in heating circuit 2/3 is
to be raised.
00:00
to
23:59
 
 
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be raised when the temperature is
raised.
0K
to
19K
 
  
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y

Settings for cooling operation
 
  
Sets the desired return set temperature when dynamic cooling is
selected
10°C
to 15°C to
30°C
 
   
Sets the room set temperature for silent cooling
The actual value is measured by room climate control station 1
15.0°C
to 20.0°C to
30.0°C
 

Sets the time programs for dynamic cooling
  


Sets the times during which dynamic cooling is blocked 00:00
to
23:59
  
  
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active for a block. Blocks
that exceed a weekday are activated or deactivated at the end of
each day accordingly.
N
T1
T2
Y
  
Sets DHW preparation
  
   
Sets the desired hot water temperature 30°C
to 45 °C to
85°C
 System-specific parameters Setting range