Operatorās Manual
Electrical Diagram
GTWY1200 SERIES 27
Symbol Description Model Qty
RH Power light LBD DC5V(red) 1
R resistor 200K1/4W 1
QF Circuit breaker DZ47-32 C16 16A 1
RCD1 Leakage protector DZ47LE-32 C16 16A 1
KM Contactor JQX-12F 24V/30A 1
M1 Motor MFWC07-(0.75)1.5KW~220V 1
FU Fuse 7A 1
TK Transformer LXB40-T 40VA ~220V/24V 1
DL Rectifier 4-1N4007/600V 1
C1 Capacitor 220UF/50V 1
SB1 Emergency Stop switch ZB2BS54C/ZB2BZ102C-6A 1
SB2 Emergency Stop switch ZB2BS54C/ZB2BZ102C-6A 1
SB3 Key switch 90173 24VDC 20A 1
BS1 Up/Down switch APEM2 10A250VAC 1
BS2 Up/Down switch ZB2BD5C/ ZB2BZ103C-6A 1
BS3 Control activate button ZB2BA3C/ZB2BZ103C-6A 1
YV Magnetic valve DC24V 1
SQ1 Microswitch AZ8 104 5A-250V/AC 1
SQ2 Microswitch AZ8 104 5A-250V/AC 1
SQ3 Microswitch AZ8 104 5A-250V/AC 1
SQ4 Microswitch AZ8 104 5A-250V/AC 1
KA1 Relay HRM1H-S-DC24V/5A 1
KA2 Relay HRM1H-S-DC24V/5A 1
KA3 Relay HRM1H-S-DC24V/5A 1
KA4 Relay HRM1H-S-DC24V/5A 1
RH1 Outrigger light LBD DC5V(red) 1
RH2 Outrigger light LBD DC5V(red) 1
RH3 Outrigger light LBD DC5V(red) 1
RH4 Outrigger light LBD DC5V(red) 1
R1 resistor 2K1/4W 1
R2 resistor 2K1/4W 1
R3 resistor 2K1/4W 1
R4 resistor 2K1/4W 1
FM Buzzer DC24V 1
SQ Microswitch AZ8 104 5A-250V/AC 1