Electric Heat Only (for heat pump unit only) Switch S1
This setting is typically used for Emergency Heating.
Wall Thermostat Enable Switch S3
A wired wall thermostat can be connected to the unit. If it is, this dip switch must be moved to the
Wall Thermostat Enable Position before the wall thermostat will begin control.
Heat and Cool Fan CON/CYC Switches S6 and S7
Allow the fan to operate in continuous or cycle modes while the unit is in heating and cooling mode.
CON (Continuous)
Allows the fan to run continuously, circulating air even when the temperature setting has been
met. This switch helps maintain the room temperature closer to the thermostat setting.
CYC (Cycle)
This setting allows the fan to cycle on and off with the compressor or electric heater. The fan stops
a short time after the temperature setting is met.
Setpoint Temperature Limit Switches S4 and S5
Provide a restricted range of temperature control within 4 ranges:
6 - 86°F
65° - 78°F
63° - 80°F
68° - 75°F