C-6000i Computerized Jigging Reel User Manual
21
parameters: the hauling power, pulling time and relax time. While hauling,
the power of the motor is periodically changed and the user can alter the
duration of each period (see Figure 11)
Figure 11
The first time when the reel pays out the line, the user must set a false
bottom at the depth where he wants the reel to start hauling. Then the reel
starts hauling the line and when it is hauled in altogether, it pays it out again
until the same depth is reached. Then it starts hauling it in again etc. The
user can make the reel decrease the depth of the false bottom by a certain
value each time it pays out the line. This is useful when the squid is moving
towards the surface e.g. due to the use of lights.
DECREASE DEPTH
Each time the line is paid out, the depth at which the reel starts to haul is
decreased by this value. The step size is 0.2 meters. Default value is zero.
This is useful when lighting is used to attract the squid up to the surface.
The squid is then constantly moving upwards and the depth that the reel must
start hauling must be decreased each time the line is paid out.
HAULING POWER
This parameter controls the hauling power. It can be varied from 0 to 99 and
the default value is 30.
PULLING TIME
When the line is hauled in the power is periodically changed. This parameter
controls the duration of the period where the power is increased (see Figure
11). The step size is 1/10 sec and the default value is 32 (3.2sec).