Symptom:
*COMPASS/TEMPERATURE MIRROR DOES CALIBRATE
POSSIBLE CAUSES
CALIBRATION PROCEDURE
COMPASS/TEMPERATURE MIRROR
TEST ACTION APPLICABILITY
1 Perform the Compass/Temp Mirror Self-Check.
Turn the ignition on.
Depress and hold the Zone/Cal button (left reading lamp button) for 20 - 25 seconds.
Turn the ignition on and then release the STEP button.
NOTE: The Compass/Temp Module will illuminate all of the VF segments
and then display a (P( for Pass or an (F( for Fail.
Exit the self-check by depressing the Zone/Cal button or cycling the ignition.
Did the Compass/Temp Mirror display an 9F9 during the self-check?
All
Yes → Replace the Compass/Temp Mirror in accordance with the Service
Information. NOTE: After replacing the CTM, it must be cali-
brated to operate properly. Refer to Overhead Console in the
Service Information or 9CTM Does Not Calibrate9 in this section.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 2
128
COMPASS/MINI-TRIP COMPUTER