Symptom:
BATTERY LOSS
When Monitored and Set Condition:
BATTERY LOSS
When Monitored: With the ignition on.
Set Condition: When the Instrument Cluster detects that the ignition has been turned on
but detects no Fused B(+) circuit.
POSSIBLE CAUSES
PDC FUSE #13 DEFECTIVE
PDC FUSED B(+) CIRCUIT SHORT TO GROUND
FUSE BLOCK #4 FUSE DEFECTIVE
FUSE BLOCK FUSED B(+) CIRCUIT SHORT TO GROUND
B(+) TO PDC #13 FUSE OPEN
B(+) TO FUSE BLOCK #4 FUSE OPEN
FUSED B(+) CIRCUIT TO INSTRUMENT CLUSTER OPEN
INSTRUMENT CLUSTER
TEST ACTION APPLICABILITY
1 Turn the ignition off.
Remove and inspect the #13 Fuse in the PDC.
If the fuse is open, replace with the proper rated fuse.
Turn the ignition on for approximately 1 minute.
Turn the ignition off.
Remove and inspect the #13 Fuse in the PDC.
Is the #13 Fuse in the PDC open?
All
Yes → Repair the PDC #13 Fused B(+) circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 2
2 Turn the ignition off.
Remove and inspect the Fuse Block #4 Fuse.
If the fuse is open, replace with the proper rated fuse.
Turn the ignition on for approximately 1 minute.
Turn the ignition off.
Remove and inspect the Fuse Block #4 Fuse.
Is the Fuse Block #4 Fuse open?
All
Yes → Repair the Fuse Block Fused B(+) circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 3
142
INSTRUMENT CLUSTER