Symptom:
P0033-SURGE VALVE SOLENOID CIRCUIT
When Monitored and Set Condition:
P0033-SURGE VALVE SOLENOID CIRCUIT
When Monitored: Ignition on or engine running. Battery voltage greater than 10 volts.
Set Condition: The PCM will set the DTC if the actual state of the solenoid does not
match the intended state.
POSSIBLE CAUSES
GOOD TRIP EQUAL TO ZERO
SURGE VALVE SOLENOID OPERATION
(A142) ASD RELAY OUTPUT CIRCUIT
(K150) SURGE SOL CONTROL CIRCUIT SHORTED TO BATTERY VOLTAGE
(K150) SURGE SOL CONTROL CIRCUIT OPEN
(K150) SURGE SOL CONTROL CIRCUIT SHORTED TO GROUND
PCM
TEST ACTION APPLICABILITY
1 Ignition on, engine not running.
With the DRBIIIt, read PCM DTCs and record the related Freeze Frame data.
Is the Good Trip displayed and equal to zero?
All
Yes → Go To 2
No → Refer to the INTERMITTENT CONDITION symptom in the
Driveability category.
Perform POWERTRAIN VERIFICATION TEST VER-5-NGC.
2 Turn the ignition off.
Disconnect the Surge Valve Solenoid harness connector.
Using a 12-volt test light, jumper across the Surge Valve harness connector.
NOTE: While actuating the solenoid wiggle the related wiring harness.
Turn the ignition on.
With the DRBIIIt, actuate the Surge Valve Solenoid.
Does the test light illuminate brightly and flash on and off?
All
Yes → Replace the Surge Valve Solenoid.
Perform POWERTRAIN VERIFICATION TEST VER-5-NGC.
No → Go To 3