15
EN
Refrigerators Service Procedures
Tilt the unit backwards to gain access to the lower
latch catch, and adjust it so that the door catches
both the upper and lower latches simultaneously
upon closing.
I
Refer to the Adjusting the Thermostat Assembly
(for CR series models only), Replacing the Handle
Assembly, or Replacing the Lower Latch Catch
sections as needed if proper adjustment is not
possible and/or not sufficient to remedy the door
issues.
7.5.1 Adjusting the Thermostat Assembly
I
This procedure is for CR series models only.
If the door does not close properly, and you feel spring
pressure just before the door latches, then the interior
light switch actuator is being squeezed between the
door and the side of the cabinet. This is due to the
thermostat assembly being installed too far forward
inside the unit. Complete this procedure to adjust the
position of the thermostat assembly remedy the issue.
10 Adjusting the CR Thermostat Assembly
1. Gently pull and remove the plunger that activates the
interior light.
2. Remove the light bulb cover.
3. Remove the Phillips-head screw behind the plunger
location and loosen the screw behind the light bulb
location approximately 1.5 turns (do not remove).
4. Gently push the thermostat assembly toward the
back of the unit approximately 1/8 in. (3 mm).
5. Use masking tape (or similar product) to temporarily
hold the assembly in place.
6. Carefully replace the plunger and verify that the door
closes properly and that the light turns off. Make any
adjustments as needed to ensure proper placement.
7. Remove the plunger and reinstall the front mounting
screw.
I
When you install the front mounting screw, it will
create a new hole in the plastic interior.
8. Complete steps 1—3 in reverse order.
7.6 Replacing the Handle Assembly
11 Replacing the Handle Assembly
CAUTION: CUT HAZARD.
The metal bar is very sharp, so use care when
handling. Failure to obey this caution could result in
minor or moderate injury.
1. Open the refrigerator door.
2. Remove the interior gasket from the refrigerator door.
3. Locate and remove the four Phillips-head screws at
the top of the door.
4. Pull up on the handle from the outside of the door to
remove the assembly.
5. Complete these steps in reverse order to install the
new handle assembly.