Technical data CD20, CD30
18
12 Technical data
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
CD20 CD30
Connection voltage: 12 Vg/24 Vg
Switch-off voltage: 10.4 V at 12 Vg
22.8 V at 24 Vg
Switch-on voltage: 11.7 V at 12 Vg
24.2 V at 24 Vg
Rated current: 12 Vg: 3 A
24 Vg: 1.5 A
Cooling capacity: –2 °C to +12 °C (28.4 °F to 53.6 °F)
Capacity: 20 l 30 l
Climatic class: N
Ambient temperature: +16 °C to +32 °C (60.8 °F to 89.6 °F)
Relative humidity: max. 90 %
Permanent inclination: max. 30°
Refrigerant quantity: 38 g (1.3 oz) 42 g (1.5 oz)
CO
2
equivalent: 0.054 t (119.05 lbs) 0.060 t (132.28 lbs)
Global warming potential
(GWP):
1430
Dimensions: fig. 1, page 3
Weight: 16.1 kg (35.5 lbs) 18 kg (39.7 lbs)
Test/certificates: