EasyManua.ls Logo

Dometic COOLMATIC Series - Connecting to Power Supply

Dometic COOLMATIC Series
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
HDC275 Installing and connecting the refrigerator
19
7.3 Connecting the refrigerator to the power supply
A
The refrigerator can be operated with a 12 Vg or 24 Vg voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Determine the required cross section of the cable in relation to the cable length
according to fig. m, page 8.
Key for fig. m, page 8
A
Before starting up the device for the first time, check whether the operating
voltage and the battery voltage match (see type plate).
NOTICE!
To avoid voltage drops and loss of performance, keep the
connection cable as short as possible and not be interrupted.
Therefore avoid additional switches, plugs or power strips.
Disconnect the cooling device and other electric consumers from
the battery before you connect the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
12 V 24 V
Cut-off voltage
10.4 V 22.8 V
Cut-in voltage
11.7 V 24.2 V
Coordinate axis Meaning Unit
l Cable length m
Cable cross section mm²
NOTICE!
Make sure the polarity is correct.
HDC275-IO-West.book Seite 19 Dienstag, 14. März 2017 8:41 20