Troubleshooting HDC275
28
12 Troubleshooting
Compressor does not run
Fault Possible cause Remedy
U
TERM
= 0 V There is an interruption in the
battery electronics connection
Establish a connection
Main switch faulty (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
U
TERM
U
ON
Battery voltage is too low Charge the battery
Start attempt with
U
TERM
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low Replacing the battery
Cable cross section too small Change the cable (see
table on page 19)
Start attempt with
U
TERM
U
ON
Ambient temperature too high
Insufficient ventilation Move the refrigerator to
another location
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor Replace the compressor
U
TERM
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics