EasyManua.ls Logo

Dometic CRX Series - Compressor Not Running (Battery)

Dometic CRX Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
CRX Troubleshooting
31
Compressor does not run (battery connection)
Problem Possible cause Remedy
U
Term
= 0 V There is an interruption in the
battery electronics connection
Establish a connection
Main switch faulty (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
U
Term
U
ON
Battery voltage is too low Charge the battery
Start attempt with
U
Term
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low Replacing the battery
Cable cross section too small Replace the cable
(fig. d, page 9)
Start attempt with
U
Term
U
ON
Ambient temperature too high
Insufficient ventilation Move the refrigerator to
another location
Condenser is dirty Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor Contact customer service
U
Term
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics