7
Safety instructions
2.0 Safety instructions
The miniBar is not suitable for the proper
storage of medication. Please observe in
addition the instructions in the medication
package inserts.
WARNING!
This miniBar is intended for free-standing instal-
lation (miniBar with unit cover) or installation in
furniture (miniBar without unit cover).
Only use the miniBar for chilling and storing clo-
sed drinks and snacks. Do not keep any perisha-
ble foodstuffs in the miniBar.
2.1 Application according to
regulations
2.4 Working upon and checking
the miniBar
2.3 Protection of children when
disposing of the equipment
Work on electrical facilities must be carried
out by authorised personnel only.
Substantial damage to property and/or inju-
ry to persons can arise through unprofes-
sional procedures.
WARNING!
Never open the absorber cooling unit! It is
under high pressure.
There is a danger of injury!
WARNING!
Anyone operating the miniBar must be familiar
with the safe handling and understand the advice
in these operating instructions.
2.2 User's responsibility
2.5 Information on coolant
Ammonia is used as a coolant.
This is a natural compound also used in house-
hold cleaning agents (1 litre of Salmiak cleaner
contains up to 200g of ammonia - about twice as
much as is used in the miniBar). Sodium chroma-
te is used for corrosion protection (1.8% by
weight of the solvent).
In the event of leakage (easily identifiable from
the strong odour), proceed as follows:
- Switch off the appliance.
- Air the room thoroughly.
- Inform authorised customer services.
For the safety of hotel guests and personnel it
was ascertained in an expert's report that no
impairment of health exists when the coolant
is discharged
When disposing of the miniBar, detach the
miniBar door and leave the storage racks in
the miniBar. In this way inadvertent entrapp-
ment and suffocation is prevented.
WARNING!