5/6 Wire Harness in P1
Connector
- Red to + Orange (UP)
- Red to + Green (GAS Down)
- Red to + Black (ELECT. Down)
Should see approximately:
9.6 VDC to 22 VDC
With no more than 1.5 volt
difference
•Turn on refrigerator.
•Check DC voltage coming from upper control board on P1 connector
•Check from - red to + Green and – red to + Black