EasyManua.ls Logo

Dometic New Dimensions - Troubleshooting a Check Light; DC Power Supply Issues; Grounding Importance

Dometic New Dimensions
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting a Check Light
DC Power Supply
Gas Supply
Grounds
Thermocouple
Burner
Reignitor
Electrode
Solenoid
Power Module
Control Panel
Installation of wire
harness
DC If DC voltage drops below 9.6VDC AC ripple
on DC line (Dirty Voltage)
Gas Supply - see components and discuss
* Grounds- a bad or loose ground can cause a Check
Light! A loose ground can create negative millivolts
Discuss
If a lower control board has recently been replaced
and the check light comes on at start up review wiring
diagram of new control board and review installation
instructions in some cases, a wiring harness needs to
be replaced and a ground wire needs to be removed.
(see next slide for example)