Icemaker Water Valve
Valve is Solenoid Operated
Ohms Value is 200 to 500.
10-15 watts will energize the coil.
Note: When the solenoid is
energized, a voltage drop may occur.
Symptom: No water in mold. Have
already manually cycled icemaker.
Test: Check ohms on solenoid coil,
see if solenoid is energized when
icemaker is calling for water.