RM10.5(S)(T), RMS10.5(X)(S)(T) Intended use
21
• The refrigerator must be installed in a recess so that it stands secure when the
vehicle is in motion. Note the following dimensions (fig. 1, page 3 and fig. 2,
page 4):
• The refrigerator must be installed with a minimum distance of 5 mm from the floor
to ensure that the door can be opened properly (fig. 3, page 4).
– Avoid placing the refrigerator directly on the floor.
– Make sure that no carpets interfere with the free movement of the door.
• The outer wall must be fitted with an air inlet vent (fig. 4 1, page 4) and an outlet
vent (fig. 4 2, page 4) with ventilation grilles so that the heat generated can be
easily released to the outside:
– Air inlet vent: Fit ventilation grille as flush as possible with the base of the
installation niche.
– Outlet vent: fit as far above the refrigerator as possible.
– The distance between the air inlet and outlet vents must be at least 750 mm
for RM10.5 and 534 mm for RMS10.5 (fig. 5, page 5).
• Fit a heat conduction plate (fig. 5 1, page 5) above the refrigerator so that the
heat does not accumulate in the vehicle.
• The distance between the refrigerator and the rear wall must be at least 15 mm
but no more than 25 mm.
• A distance of more than 25 mm between the refrigerator and rear wall leads to
poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator to create adequate air inlet and outlet
ventilation (fig. 6, page 5). Use a ventilation plate, for example, to do this.
RM10.5(S)(T) RMS10.5(S)(T) RMS10.5X(S)(T)
Refrigerator Overall dimension in mm
Height (A) 821 821 821
Width (B) 523 523 523
Depth (C)
(excludes control knob 5 mm)
548 548 603
Recess Dimension in mm
Height (H) ≥829 ≥829 ≥829
Width (W) ≥525.5 ≥525.5 ≥525.5
Depth (D) ≥563 ≥563 ≥618
DometicRM S10_INM_4445103083_EMEA18_20xx-xx-xx.book Page 21 Wednesday, April 5, 2023 3:52 PM