26
flashing +
acoustic
signal 20 s
Check burner, burner nozzles, if necessary contact
Customer Service and arrange replacement
Burner defective or coo-
ling unit defective
7
3
4.20 Information on failure display
and trouble-shooting
4.20.1 Status indicators
Operation with on-board 12 V power supply
Indicator
Fault
Remedy
flashing +
acoustic signal
20 s
Check mains power connection, mains voltage, fuse120V mode: "120V" not
available or voltage too
low
Refrigerators with an electronics system
(MES, AES) indicate the occurence of a
malfunction by the LED or display flashing.
If a malfunction occurs, the indicator LED
"Failure" (8) flashes simultaneously. In the
case of AES models an acoustic alarm
sounds.
1 2 3 4 5 6 8
7
= Button ON / OFF
= Energy selector switch 120 V AC
= Energy selector switch GAS
= Energy selector switch 12V DC
2
1
3
4
= selector switch "AUTOMATIC"
= temperature level button
= temperature level display
= fault LED / GAS FAULT reset button
6
5
7
8
8
2
flashing +
acoustic signal
20 s
Arrange replacement of 120V heating element,
contact Customer Service
120V mode: 120V hea-
ting element defective
7
2
flashing
contact Customer ServiceTemperature sensor
without contact or
defective
7
flashing +
acoustic signal
20 s
Arrange replacement of 12V heating element,
contact Customer Service
12V mode: 12V heating
element defective
7
4
flashing +
acoustic signal
20 s
Check 12 V connection, on-board battery, fuse
AES: Check D+ signal
12V mode: "12 V" not
available or voltage too
low
8
4
flashing +
acoustic signal
20 s
GAS/Automatic mode:
Flame not ignited
8
3
Check gas supply (gas bottle, gas valve)
Press the button after clearing the fault.
Acoustic signal,
15 s, at 2 minute
intervals
Interior lighting is swit-
ched on
Close door, check door contact
Before notifying the authorised Service Center,
please check whether:
the instructions in section "Operating the
refrigerator" have been observed.
the refrigerator stands level.
it is possible to operate the refrigerator with
any available power source.
MES
AES
Fig. 41
Fig. 42
1 2
3
4 6
7 8
Refrigerator operation
289 0317-13_USCD_EN_RMx8xxx-Operation_N2_Layout 1 03.02.2014 08:05 Seite 26