HEATING ELEMENT
(3-WAY
MODELS ONLY)
Check the heating element with ohms resistance using a properly calibrated ohm meter.
You should obtain the following readings, plus or minus 10%:
RM2310
1.15 OHMS
RM2410
1.15 OHMS
RM2510
.82
OHMS
RM2610
.67
OHMS
RM2810
.67
OHMS
RM2453
.83
OHMS
RM2553
.83
OHMS
A continuity reading will indicate an open or complete circuit.
FLAME INDICATOR METER
If the
millivolts
from the thermocouple are 5 millivolts or more, the red needle in the meter
should
be in the green section.
LP GAS REQUIREMENTS
The LP gas pressure to the refrigerator should be 11 inches water
column with half of all BTU’s of the RV turned on. With all other
appliances turned off, the pressure to the refrigerator should not
exceed 12 inches water column. To check the gas pressure when
the refrigerator is operating, there is a pressure test housing
located just prior to the orifice.
-
--
*‘-
PRESSURE TEST HOUSING
LP GAS COMPONENTS
SHUT-OFF VALVE
To check the shut-off valve, remove and inspect
for any obstructions.
REFRIGERATORS WITH
BOTTOM
MOUNT
CONTROLS
MANUAL GAS SHUTOFF VALVE
REFRIGERATORS WITH TOP MOUNT CONTROLS
MANUAL
GAS VALVE
/
MANUAL
GAS VALVE
12