THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE
RM2310,
RM2410,
RM2510, RM2610 , RM2810, RM2452, RM2453, RM2552
AND RM2553 REFRIGERATORS
SYMPTOM
CAUSE
1.
No operation.
2. No electric operation.
3.
No gas operation
-
no spark.
4. No gas operation
-
sparks but no flame.
5.
No cooling on any mode.
6. No cooling on gas
-
cools properly on other
mode(s).
7. No cooling on electric
-
cools properly on other
mode(s).
Operation
Wiring
Switch
Operation
AC Volts
Heating Element
Thermostat
Switch
Wiring
Operation
DC Volts
Igniter
Electrode
High Voltage Cable
Switch
Wiring
Operation
LP gas
Filter
Orifice
Burner
Shut-off Valve
Safety Valve
Thermocouple
Thermocouple Adapter,
(Top Mount Controls Only)
Operation
Level
Ambient Temperature
Cooling Unit
LP Gas
Thermostat
Filter
Orifice
Burner
Flue Baffle
Flue Tube
AC Volts
Heating Element
Thermostat
Switch
Wiring