AC VOLTAGEREQUIREMENTS
The proper operating range is 100 to 132 volts. Check the AC volts at the receptacle where the refrigerator is attached.
If voltage drops below 100 volts, cooling efficiency will decrease with voltage decrease.
AC COMPONENTS
HEATING ELEMENT
To check a heating element, remove the heater leads from the terminal block
and measure for proper resistance across the two leads.
You should obtain the following readings, plus or minus 10%:
RM2310 92
RM2410 92
RM2510
75
RM2610 48
RM2810 44
RM2452 69
RM2453 69
RM2552 69
RM2553 69
DC VOLTAGE REQUIREMENTS
The operational range is 10.5 to 15 volts DC. Check for proper voltage at the terminal block or blocks at the back of
the refrigerator. The power supply to the refrigerator must be fused.
DC COMPONENTS
SWITCH (BOTTOM MOUNT CONTROLS)
A. Remove all wires from the assembly.
For the DC mode,
continuity should exist between terminals 1 and
1A
and 2 and2A.
(3-Way
Models Only)
For the AC mode, you
should have continuity between 4L and 4A and 5N and 5A.
RM2310
&
RM2410 SWITCH ASSEMBLY
DC Mode
AC Mode
DC Mode
AC
-Mode