B.
The RM251
O/RM261
O/RM2810
selector switch should be checked for continuity in the following manner. Remove
all wires from the assembly.
For the DC mode, continuity should exist between terminals
1
and
IA
and2 and 2A. For the gas mode, you should
have continuity between 3 and 3A.
For the AC mode, you should have continuity between 4L and 4A and 5N and 5A.
RM251
O/RM261
O/RM2810
SWITCH ASSEMBLY
Gas Mode
DC Mode
\
AC Mode
DC
Mode
AC Mode
Gas Mode
SWITCH (TOP MOUNT CONTROLS)
Remove all wires from the assembly.
For the DC Mode
(3-Way
Models ONLY), continuity should exist between terminals 5 and 5a and 6 and 6a.
For the AC Mode, continuity should exist between terminals 1 and la and 2 and 2a.
For the Gas Mode (on refrigerators equipped with automatic
REIGNITERS
ONLY), continuity should exist between
terminals 4 and 4a.
RM2452/RM2453/RM2552/RM2553 SWITCH
Gas Mode
AC
Mode
1
‘DC
Mode
Gas Mode