2
SYMPTOM CAUSE
7. Insufficient cooling on AC - cools properly on other mode(s) AC Volts
Heating Element
Lower Circuit Board
8. Insufficient cooling on DC - cools properly on other mode(s) DC Volts
Heating Element
Wiring
Lower Circuit Board
9. Insufficient cooling on gas - cools properly on other mode(s) LP gas
Orifice
Flue Baffle
Flue Tube
Flue Cap (if equipped)
Burner
Lower Circuit Board
10. Freezes Thermistor
Thermistor Adjuster
Lower Circuit Board
Upper Circuit Board
11. Changes preset mode Operation
DC Volts
Wiring
Upper Circuit Board
Lower Circuit Board
12. Check light on DC Volts
Wiring
LP Gas
Manual Gas Valve
Solenoid
Orifice
Burner
Lower Circuit Board
Thermocouple
13. Interior light on when door is closed Wiring
Door Switch
Door Position
14. Rapid formation of frost Food Storage
Interior Liner to Frame
High Humidity
Air Leaks
15. Water on frame Interior Liner to Frame
High Humidity
Air Leaks
Climate Control Heater