16
Fig. 7
Fig. 8
Manual energy selection / automatic igniti-
on (RMD 8xx1) MES :
11= Power ON/OFF switch
= Energy selector button 230V AC
= Energy selector button GAS
= Energy selector button 12V DC
= Pushbutton ON/OFF frameheating
= Temperature level selection
= Temperature level display
= Indicator LED failure /
Reset button GAS FAILURE
2
1
3
4
6
7
1 2 3 4 6 7 8 9
240V AC operation
n Select "Mains voltage" by pressing button (2)
n Set temperature step by pressing button (7)
Switching ON/OFF
n Switch ON by pressing button (1), 2s
n Switch OFF by pressing button (1), > 2s
12V DC operation (vehicle’s battery)
n Select "Battery voltage" by pressing button
(4)
n Set temperature step by pressing button (7)
Gas operation
n Select
"Gas" by pressing button (3)
n Set temperature step by pressing button (7)
Manual operation
n Select energy source with buttons (2,3,4)
n Set temperature step by pressing button (7)
Switching ON/OFF
n Switch ON by pressing button (1), 2s
n Switch OFF by pressing button (1), > 2s
Automatic operation
n Change over to
"Automatic" with button (5)
Automatical energy selection (if available)
Sequence of priority: 1.) Solar (12V DC)
2.) 230V AC
3.) 12V DC
4.) Liquid gas
n Set temperature step by pressing button (7)
Automatic energy selection / automatic
ignition (RMD 8xx5) AES :
1 = Power ON/OFF switch
= Energy selector button 230V AC
= Energy selector button GAS
= Energy selector button 12V DC
= Selector button “AUTOMATIC”
= Pushbutton ON/OFF frameheating
= Temperature level selection
= Temperature level display
= Indicator LED failure /
Reset button GAS FAILURE
2
1
3
4
5
6
7
8
9
1 2 3 4 5 6 8 97
8
9
Refrigerator operation

Table of Contents