Connecting the refrigerator RML9336
20
Secure the power supply line to the heating element (fig. k 13, page 8) with a
20 A fuse.
Secure the power supply line to light (fig. k 7, page 8) with a 2 A fuse.
Connect the heating element with the shortest possible cable.
Run the cable to the heating element via a relay (fig. k 11, page 8) controlled by
an ignition socket to prevent the battery from completely discharging if the
engine is switched off accidentally.
Except for: S+
Connect a 12 V continuous supply to the connection for lighting/electronics.
D+
In automatic mode, the refrigerator selects the most favourable mode available. The
refrigerator is only operated with direct current when the vehicle engine is running.
The electronics of the refrigerator uses the signal D+ from the light system to detect
the running engine.
Connect the D+ connection to the controls (fig. k 8, page 8) with the
respective terminal of the vehicle.
S+
In automatic mode, the refrigerator is first powered with DC power from the vehi-
cle's own solar system. The refrigerator electronics uses the S+ signal of the solar
charge controller to detect a solar system. The solar charge controller must have an
AES output.
Connect the S+ connection on the controller (fig. k 10, page 8) ) to the
respective terminal of the solar charge controller.
Connect the heating element (fig. k 18, page 8) to the battery.
The 12-V-battery is being loaded via solar collector
Suitable solar charge controllers are available from specialist dealers.
The manufacturer recommends, for example:
Büttner MT 300-S
(www.buettner-elektronik.de)
Votronic MPP 240 Duo Digital
(www.votronic.de)
RML9336-I-EN-DE.book Seite 20 Mittwoch, 17. Januar 2018 1:54 13