RML9336 Troubleshooting
27
✓ A beep sounds.
✓ The error has been reset.
Fault messages
Code LEDs Fault Typ e Solution
W01
Temperature sensor in the
refrigerator compartment
defective
Warning Replace the temperature
sensor.
E03 No connection between
power module and
display
Error Check the connection
between the power
module and display.
Reset the error manually.
W05 AC power not connected
or AC voltage < 190 V
Warning Connect the refrigerator to
AC or select a different
energy type, e.g. gas or
DC.
W06 DC power not connected Warning Connect the refrigerator to
DC or select a different
energy type, e.g. gas or
AC.
E07 No cooling capacity in
gas mode
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
E08 No cooling power in AC
operation
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
E09 No cooling power in DC
mode
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.