Maintenance RML9336
30
10 Maintenance
!
I
➤ Have the gas system and connected flues inspected before initial operation and
then every two years by an authorised professional to ensure they comply with
the European standard EN 1949.
➤ The gas burner must be cleaned of impurities whenever necessary or at least
once a year. When using LPG (tank or refillable cylinders), the maintenance inter-
val is reduced to twice or four times a year, depending on the degree of contam-
ination. This can be determined by a reduced cooling capacity in gas mode.
➤ Keep a record of any maintenance performed on your refrigerator.
10.1 Cleaning the gas burner
!
➤ Remove the ventilation grille (fig. f, page 7).
➤ Press the catch below the burner cover inwards, and pull off the burner cover
(fig. g, page 7, A or B).
➤ Clean the burner pipe of coarse impurities using a suitable cleaning brush with
soft bristles (fig. h, page 8, A or B).
➤ Blow out the burner pipe with compressed air through the slots in the burner
pipe (fig. i, page 8, A or B).
➤ Attach the burner cover.
✓ The burner cover is fixed in place when it audibly clicks into place.
WARNING!
Working on gas and electrical installations may only be performed by
qualified technicians.
NOTE
Have the refrigerator checked if the vehicle has not been used for a long
time. To do this, contact the customer service.
WARNING!
• Close the gas valve to the refrigerator before cleaning the gas
burner.
• Allow the burner to cool down before cleaning it.
• Do not modify the gas equipment. The gas burner can be cleaned
without removing the gas equipment.
RML9336-O-EN-DE.book Seite 30 Mittwoch, 30. Mai 2018 1:26 13