RML9430, RML9431, RML9435 Using the refrigerator
23
Gas operation (fig. 6, page 4)
!
I
Make sure that the gas supply is turned on.
Turn the power selector switch to the position.
Turn the temperature control to the maximum level (A).
Press in the temperature regulator and hold it down.
Press in the battery igniter as well and hold it down (B).
The burner is ignited automatically. The needle of the pilot light moves to
the green zone once the burner has ignited (C).
Press and hold down the temperature regulator for another 15 seconds.
7.3 Switching on the refrigerator (RML9431/RML9435)
Press and hold the button for two seconds.
The refrigerator starts with the last type of power selected.
Operating with AC power supply
Press the button.
Operating with DC power supply
I
Press the button.
WARNING! Fire hazard!
Never operate the refrigerator with gas at petrol stations.
NOTE
When operating with LPG, the burner must be cleaned frequently
(two or three times a year).
NOTE
Only select the operating mode with direct current (battery mode)
if the vehicle engine is running and is providing sufficient voltage
to the light system or if you are using a battery monitor.