2.4 Gas valve GV 100
This component includes two gas valves in serial
mounting (as part of gas safety device).
voltage supply : per valve approx. 0,7V - 0,9V
(switched on gas mode)
inductive resistance : per valve approx. 48-50
Ohm
Measuring points: voltage and resistance
valve 1: Pin 1 – ground
valve 2: Pin 2 – ground
Components
2.5 Gas burner
The burner and the chimney must be cleaned
regularly, at least one time a year.
If Autogas is used, Dometic recommends a
maintenance every half year, as the contamina-
tion risk of the burner is higher, due to the bur-
ning of the auto gas.
2.5.1 Cleaning of burner
Fig 23
1 Ignition electrode
2= Ionisation electrode
3= Ground (connection to burner control device)
1
1
2
3
2
3
A listing of burners and jets can be found in
chpt. 6.1 .
Fig 22
GND
Pin 1
Pin 2