36
5.8 Flowcharts
Interior light does not
work
Interior light not pro-
grammed?
-> programm via service-
mode
Wiring not ok?
-> check wiring (connector
X111 or 114=door switch
input; X109= light output);
note polarity for LED light!
LED light module
defective?
-> exchange light module
MES / AES board
defective?
-> exchange main board