RM(x)8xx6 Troubleshooting
39
9.1 Fault messages and signal tones
I
All faults are indicated with a warning symbol, a fault ID and a beep. The beeping
lasts for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the last fault. The underlying faults are
displayed after the last fault has been confirmed.
The refrigerator is not
adequately cooling.
The ventilation around the
cooling unit is not sufficient.
Check that the ventilation grill is
not obstructed.
The evaporator is iced up. Check whether the refrigerator
door is properly closed.
Make sure that the refrigerator seal
fits correctly and is not damaged.
Defrost the refrigerator.
The temperature is set too
high.
Set a lower temperature.
The ambient temperature is
too high.
Remove the ventilation grill for a
while so that warm air can escape
quicker.
Too much food at once was
placed in the refrigerator.
Remove an item.
Too much warm food at once
was placed in the refrigerator.
Remove the warm food and leave
it to cool down before putting it in
again.
The refrigerator has not been
operating for very long.
Check the temperature again after
four or five hours.
The refrigerator is out
of order. The refrigera-
tor can not be switched
on by the control
panel.
The DC fuse is defective. Check the DC fuse (2 A).
NOTE
All faults of the type ERROR must be reset manually.
All faults of the type WARNING are reset automatically once the fault
has been rectified.
Contact customer service if you cannot remedy the fault yourself.
Fault Possible cause Proposed solution