EasyManua.ls Logo

Dometic SKE 180 - MiniBar Installation Guidelines; Critical Installation Requirements

Dometic SKE 180
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
8
7.0
1. The refrigerator must be level both directions
2. There sould be 20mm clearance to the wall
3. Ventilation must be provided as shown in
alternatives A,B,C or D
4. The ventilation duct must at least measure
105mm x the wt
dth of the refrigerator
5. Only the entire cooling unit must project into
the duct as shown
6 Air p
assing through the duct must not be
preheated by any source of heat
7. Ventilation grills, if used, must have openings
of at least 200cm² each
Please follow the installation details below
carefully. Guarantee is valid for products
installed as described only.
IMPORTANT:
20mm20mm
20mm
20mm
200cm²
200cm²
200cm²
200cm²
200cm²
200cm²
200cm²
200cm²

Related product manuals