CF18 – CF60 Operation
17
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
Selecting the battery monitor mode (CF18)
➤ Slide the selection switch (fig. 3 4, page 9) to select the battery monitor mode.
Selecting the battery monitor mode (CF25, CF35, CF40, CF50, CF60)
➤ Switch on the cooler.
➤ Press the “SET” button (fig. 4 4, page 10) three times.
➤ Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons
to select the battery monitor mode.
✓ Display will be as follows:
Lo (LOW), Πed (MED) or HI (HIGH)
✓ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
CF18
CF25, CF35, CF40,
CF50, CF60
Battery monitor mode LOW HIGH LOW MED HIGH
Switch-off voltage at 12 V
10.4 V 11.5 V 10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.5 V 12.5 V 11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
22.1 V 24.0 V 21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.6 V 25.4 V 23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC power supply, set the
battery monitor to the “LOW” position.
CF18-CF60-O-AUS.book Seite 17 Dienstag, 17. September 2019 8:49 08