Maintenance & Adjustment
D760.H03E-001.H1907 169
Supercharger maintenance
Please refer to the Cummins engine operation and maintenance manual accom-
panying the vehicle.
Maintenance of urea tank
Periodic maintenance cycle
Check the maintenance period refer to
page 208
1. Clean the vent valve with compressed air.
2. After injecting urea, the rubber plug should
be blocked to prevent urea spillage.
3. There is a drain port at the bottom of the
urea tank to discharge the sediment.
Filter element for urea tank
Replacement cycle
Check the maintenance period refer to
page 208
Replacement method:
1. The filter in the vehicle urea tank is used to
prevent foreign matters that may be
suspended in the vehicle urea from entering
the injection system. Debris may cause
permanent damage and premature failure to
the post-treatment metering pump.
3. The filter in the vehicle urea tank is located
inside the vehicle urea tank, below the liquid
level temperature sensor.
CAUTION:
1.Before using containers or funnel for distributing, treating or storing
vehicle urea, make sure to thoroughly wash away any impurities with
water and then rinse with distilled water.
2.Do not use tap water for rinsing instruments or vehicle urea tanks for
transporting vehicle urea. Tap water will contaminate vehicle urea.
3.If distilled water is not available, rinse with tap water and then rinse
with urea in the car.
4.Failure to carry out maintenance as required may result in torque limit
or speed limit.
1. Urea tank filter element