EasyManua.ls Logo

Doosan D18S-5 - Hydraulic System Adjustments and Tests

Doosan D18S-5
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vehicle Systems Testing and Adjusting
49
Problem: Brake will not make application.
Probable Cause:
1. Leakage or low fluid level.
2. Lining surface looks like glass (glazed), or worn.
3. Oil or brake fluid is on the lining.
4. Air in the brake hydraulic system.
5. Bad master cylinder.
6. Linkage is not in correct adjustment, or is bent.
Problem: Not braking evenly, or rough feeling of
braking (chatter).
Probable Cause:
1. Lining surface looks like glass (glazed), or worn.
2. Oil or brake fluid is on the lining.
3. Bad contact between the lining and drum.
4. Loose lining.
5. Brake drum out of round.
6. Loose wheel bearing.
7. Bad wheel cylinder.

Table of Contents