Operation Section
-129-
NO START
Checks Action
DEFINITION: The engine cranks OK but does not start.
Preliminary Checks None
ECM Checks
Use the DST to :
Check for proper communication with both the ECM
Check all system fuses engine fuse holder. Refer to Engine Controls Schematics.
Check battery power, ignition power and ground circuits to the ECM. Refer to
Engine Control Schematics. Verify voltage and/or continuity foreach.
Sensor Checks
Check the TMAP sensor.
Check the cam angle sensor for output (RPM).
Fuel System
Checks
Important: A closed LPG manual fuel shut off valve will create a no start condition.
Check for air intake system leakage between the mixer and the throttle body.
Verify proper operation of the low pressure lock-off solenoids.
Verify proper operation of the fuel control solenoids.
Check the fuel system pressures.
Refer to the LPG Fuel System Diagnosis.
Check for proper mixer air valve operation.
Ignition System
Checks
Note: LPG being a gaseous fuel requires higher secondary ignition system voltages
for the equivalent gasoline operating conditions.
1. Check for the proper ignition voltage output with J 26792 or the equivalent.
2. Verify that the spark plugs are correct for use with LPG.
Check the spark plugs for the following conditions:
Wet plugs.
Cracks.
Wear.
Improper gap.
Burned electrodes.
Heavy deposits.
Check for bare or shorted ignition wires.
Check for loose ignition coil connections at the coil.