L1 NON-INSULATED PARTITION INSTALLATION INSTRUCTIONS
NonInsulatedPartitionInstallationInstructions
UsethefollowinginstructionstoinstallHillphoenix
noninsulatedpartitions.Itisrecommendedthat
allshelvesanddeckpansfrombothsidesofthe
partitionberemovedtoavoidanypotential
damageorinjury.
Step1
:Mountthetwoverticalretainerbracketsto
theshelfstandard(figures1&2)usingthesupplied
tekscrews(8‐18x3/4).Therectangularcutoutsin
theretainersmustalignwiththerectangularslots
intheshelfstandard.VerticalRetainerBracket#1
shouldbelocatedbelowthe3
rd
slotfromthetop
andVerticalBracket#2shouldbelocatedabove
the6
th
slotfromthebottom.Thegroovesinthe
verticalretainerbracketsmustbecenteredonthe
casetocasejoint.Thetekscrewsaretobedrilled
throughthepre‐drilledholesintheretainer
bracketsasshowninfigure3.Notethatthe
verticalandhorizontalretainerbracketsare
identical.
Step2:
SlidethePlexiglaspartitionintothevertical
retainerbrackets.Usethesuppliedretainerbolts
andnuts(8‐32x1/2)tosecurethePlexiglas
partitiontotheverticalretainerbracketsasshown
infigure3.DrilladditionalholesinthePlexiglasif
thepre‐drilledholesinthePlexiglasdonotlineup
withtheholesintheretainerbrackets.
Step3:
SlideHorizontalRetainerBracket#2onto
thebottomofthePlexiglaspartitionasshownin
figure2.Alignthepartitionparalleltothepipe
chaseandsecurethebracketbydrillingdirectly
intothepipechaseusingthesuppliedtekscrews.
SlideHorizontalRetainerBracket#1ontothetop
ofthePlexiglaspartitionandsecureittothetop
flueofthecaseusingthesuppliedtekscrews.
Securethepartitionusingtheretainerboltsand
nutsinthehorizontalretainerbracketsasdonein
step2.
Figure1:TopofPlexiglasPartition
Figure2:BottomofPlexiglas
Figure3:VerticalRetainerBracketInstallation