Pre-Installation Installation Training
A70622-D1
108/192
The LASER configuration may achieve two level of safety in order to be compliant with standard
ISO13849. One basic level “PLc ” and one higher safety level “PLd”.
To achieve a level PLd three conditions are required :
- The standard industrial interface board (ENM70867) must be replaced by a specific (ENM70867)
- Two (2) wires from the switch must be connected to this specific board ( instead only one on
standard version)
The level must be selected in the LASER application (available from software version LO5.7)
Note : When the customer orders this option, the cabinet will be delivered with the current
PLc board. A PLd board will be also delivered that must be mounted at installation.
The
technician should upgrade from PLc to PLd
by using Spare parts sheets provided in this
book (section Troubleshooting).
Step 7 : Connect electrically the switch to the Industrial interface board
ENM70867
ENM70867
Standard version : PLc application
Optional version : PLd application