Troubleshooting
A70622-D1
164/192
SPS Replacing Galvo head Assy (ENM70773) for 90° Head
1 / 2
Special
Tools
Allen Key 2mm - Allen Key 3mm -
Hexagonal key - Depth gauge
Prerequisite
Switch off the laser / Unplug from the mains supply/ Disconnect the cable
Remarks
WARNING: after opening IP65 head, gaskets must be replaced
This procedure is applicable to HD head model
1
Perform step 1 to 3 from the SPS Replacing Galvo head Assy (ENM70863)
2
You should have access to the
optical plate
Disconnect the white ribbon cable.
3
Remove the grey tape on the
bottom part of the optical plate
Remove the CHC screws as
shown on the picture.
Please do not touch the other
screws
4
Remove the old galvo from the
plate