Printer description
A70622-D1
49/192
ES500 I/O customization:
The interface cable with the Laser is equipped with a M12 connector (5-pin connector (M12-
male). It has the following pin assignment :
The following table gives the connection and the setting to perform according to required
working modes : Stand alone or Laser remote.
Mode
Internal
Switch
Scheme Laser settings
Stand alone :
standard
configuration
OFF
position
Standard position
Shunt pin-1 and pin-2
M12-2
No specific Laser settings
Laser remote
Stop/Start
signal
The extractor
starts when the
dry contact in
the laser is
closed
ON
position
Connection to synchronize the
start and stop of the extractor with
LASER
M12-1
M12-2
COM
NO
Extractor
I/O output DS10 has to be set to
“Fume ext Start/Stop”
GND
Clogged alarm
Pre-clogged alarm
+24 V DC
Remote start/stop