Page 10 of 12
CODE CIRCUITRY ELECTRICAL RATING
“E” EXQ
or
O” OP-Q
Single Pole Double Throw (SPDT)
UL and CSA Listed:
15 amps, 125, 250 or 450 VAC
0.50 amp 125 VDC
0.25 amp 250 VDC
“D” EXD-Q
or
“F” OPD-Q
Double Pole Double Throw (DPDT)
UL and CSA Listed:
10 amps, 125 or 250 VAC
0.30 amp 125 VDC
0.15 amp 250 VDC
T A B L E 2 W I R I N G D I A G R A M S
STANDARD SWITCH
Green – Ground
Blue – N.O. 1
Black – Com 1 Red – N.C. 1
Blue – N.O. 2
Black – Com 2
Red – N.C. 2
CODE CIRCUITRY ELECTRICAL RATING
“K” Hermetic
030
Single Pole Double Throw (SPDT)
UL, CSA and FM Listed:
11 amps, 125/250 VAC
5 amps Res, 25 VDC
0.50 amps, 125 VDC
“D” EXD-Q
or
“F” OPD-Q
Double Pole Double Throw (DPDT)
UL, CSA and FM Listed:
11 amps, 125/250 VAC
5 amps Res, 28 VDC
0.50 amps 125 VDC
HERMETICALLY SEALED SWITCH
Green – Ground
Blue – N.O. 1
Black – Com 1
Red – N.C. 1
Purple – N.O. 2
Yellow – Com 2 Black – N.C. 2
Red – N.C.
Blue – N.O.
Green – Ground