EasyManua.ls Logo

Dover OPW SiteSentinel iTouch M1500 - 30-3221-1 A, -1 B Interstitial Level Sensors

Dover OPW SiteSentinel iTouch M1500
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Doc. No.: M1500, Rev. 6
Page 58 of 127
67733 Gross Point Road 900 Santa Fe Dr.
1.25 30-3221-1A, -1B Interstitial Level Sensors
These two types of interstitial level sensors are used primarily in the interstitial area of a double walled tank.
The sensors have a float switch that activates in the presence of a liquid. The 30-3221-1A is constructed from
chemical resistant, non-metallic material and the 30-3221-1B is constructed from brass.
These sensors can also be used in sumps, dispenser pans and other locations where the presence of a liquid
could indicate that a leak has occurred. Combined with a vapor sensor, this interstitial sensor can be used to
monitor wet wells to ensure that a liquid is normally present. In the event of a break in the cable the system will
activate an alarm.
30-3221-1A, -1B Specifications
Operating Temperature
20 C to +50 C (4 F to +122 F)
Dimensions - 30-3221-1A
3.4 cm (1.3 in) dia. x 10 cm (3.9 in) long
Dimensions - 30-3221-1B
3.5 cm (1.4 in) dia. x 9.0 cm (3.5 in) long
Cable
4.5 m (15 ft) gas & oil resistant
NOTE: To ensure safe operating conditions the sensor has been designed to connect to OPW Fuel
Management Systems’ controller only.