2.3 Components & Diagrams
2.3.1 Main Board Components
Components of the FSC3000 Main Board
The power supply supplies 12 VDC to the main board. This lets the main board run logic and
communication circuit devices. The main board contains all communication circuits for a back-office PC,
Petro-Net communication to the FITs and PCMs, and Ethernet communication. The main board also
manages fleet network host modem, journal printer, pass-thru port communications and USB key operation.
The SIMM card contains the application program for the operattion of all ordered options (i.e.,
card/transaction memory, fleet networks, DPC, etc.) The SIMM card also contains a backup battery to
maintain all data in memory in the event of a power loss. Remove the battery-insulating strip to activate a
SIMM memory module. Gently remove the yellow strip at this time. It is recommended that the SIMM module
be reseated.
2.3.2 Parts Listings & Accessories Exploded View
FSC3000 Parts List
Item No. Part Number Description
1 75-2037 FSC3000 Internal Modem
2 R20-0380 FSC3000 Main Board
3 R20-0381-03* FSC3000 SIMM Module (*requires configuration)
4 20-1517-05 FSC3000 Printer Cable
5 20-1613 RJ45 to RJ45 Ethernet Cable
6 20-1517-01 Network Modem Cable
7 20-1520-01 PC/CRT Cable
8 75-0108 USB Key
9 20-4089 Display Assy. External FSC3000
10 75-2059 Bluetooth M-7EM