Gateway Connections:
NOTE: The colors of the cables in the illustration are used to show the routing of the wires
only. Power cables are shown in black.
IP Gateway (Abierto - p/n 20-6013)
1. Serial port 1 on the Gateway is the connection to the card host. Use the supplied 20-1517-01 cable to
connect this port to FSC3000 serial port 5, the primary authorization port (green cable in the
illustration).
2. Inbound Access to the FSC for remote configuration or transaction polling (ex. Phoenix) can be
provided through the second serial port on the IP Gateway (Abierto version only). This eliminates the
need for an Ethernet connection directly to the FSC3000. To make this connection, connect another
M1700 FSC3000 Installation Manual | Dover Fueling Solutions 30