IMPORTANT: The FSC3000's network port setting is set to 2101 during manufacturing. It
might have been changed during the FSC3000's network setup. Make sure the port settings
match.
USB Memory Key Operation
A USB memory key can be inserted into the USB port on the FSC3000. The key can be used for two
purposes:
l It will store transaction data in a format that can be imported into Phoenix™.
l It will process a card update file created by Phoenix. (This is an optional feature.)
FSC3000 USB Key Setup
The FSC3000 must be set up to function with the USB key using ARTWare, or set manually by using the [Set
Journal] command.
The default Phoenix site ID is 000. This setting disables the USB key from recording transactions.
Set the Phoenix site ID to the desired number. This number will be stored with each transaction record and
imported into Phoenix™ for reporting purposes. Each site should have a unique number to identify where the
transaction took place.
USB Key Card Update Operation
The FSC3000 detects when a key is inserted and displays the message [USB Key Inserted]. The FSC3000
checks to see if the key contains a card update file with a matching site ID. If so, the message [Processing
Card Updates] will be seen while the FSC is updating the positive card file.
When complete, the card update file is deleted and the display will show [Card Update Complete –
Remove Key].
The Key must then be removed. It can be reinserted, or a different key can be inserted to begin storing
transaction data.
USB Key Transaction Recording Operation
The FSC3000 detects when a key is inserted and displays the message [USB Key Inserted]. If no card
update file is present on the key, the FSC3000 will use the key to store transactions. If there is an existing
transaction file, new transactions will be appended to the file. If no transaction file exists, one will be created.
In either case, the message [USB Key Logging Transactions] will be displayed.
Removing a USB Key with Recorded Transactions
IMPORTANT: Never remove the USB key without following these steps first; corrupted data
could result.
1. Press one of the function buttons on the FSC3000 until the [USB Key Inserted] message is displayed.
2. Press the function key one more time to display the message [Log All Transactions Now?].
3. Press the <No> (Left) function button to select. The message [Remove Key?] is displayed.
4. Select <Yes> and wait while the system writes the end-of-file marker to the key. The message [Please
Remove Key] will be displayed and three beeps will be heard.
M1700 FSC3000 Installation Manual | Dover Fueling Solutions 44