3.2.5.2 Gilbarco CRIND-specific
Direct connect to CRIND loops. Connect the 12-3046 RJ45 cable from the CN3 port of the DTC board to CN4
of the DPC board.
Attach the CRIND communication loop wires to terminal blocks CN5 of the DPC board. If connecting more
than four (4) dispensers, connect loop one (1) to the Gilbarco D-Box using the supplied cable as shown
below.
Connect the Gilbarco Universal distribution box (D-Box) to DPC interface with the 20-1689 interface cable.
IMPORTANT: Make sure that the the Gilbarco D-Box is set up for current loop.