16
Push product tube up, then use wire cutters to cut and remove the retainer.
17
Lower and remove product tube.
18
Install new retainer.
19
Reinstall outlet casting.
20
Install new o-rings on the ends of new tube.
21
Install new tube aligning upper end with the outlet and lower end with the valve and, then
firmly push upper end into the retainer in the outlet first and push the lower end up into the
valve.
22
Be sure that the tube is firmly up into the valve and then insert tube retainer pin.
23
Reinstall hoses.
24
Turn on power to dispenser.
25
Reset the shear valve.
26
Run a test sale to clear air from the line and check for leaks.
27
Reinstall top cover plate.
28
Reinstall valance.
29
Reinstall lower column cover.
30
Reinstall upper column cover by firmly snapping it back into place.
Figure 6.24: Valance End Cover