ClassificationDescriptionError/EventNo.
A# consecutive fillings (F61.00) with low flow rate (%
level set in F61.01) reached.
Consecutive number of Low
flow rate fillings
33
S21/S22 device no indicate which GHM had low flow
rate.
Possible cause can be Filter Clogged.
BFilling terminated due to STOP button press.STOP button pushed34
BBlend Error exceeds configured max value (%) ( ->
F.18 )
Blending out of tolerance35
BVolume ratio between the assigned meters is < 0,5%No flow on one meter at high
speed/blender pump.
36
A10 fillings in row with vapour recovery flowrate out
of tolerance
VAP Monitor 10 fillings bad37
A72 hours elapsed after error code 37VAP Monitor 72h elapsed38
AInternal VAP Monitor System (Vaporix) error or not
connected.
VAP Monitor internal error39
AVAP Monitor System (Vaporix) has been reset.VAP Monitor Reset40
BErrors from motorMotor feedback41
AVAP system not calibrated yet.Vap not calibrated42
AValve current is low (e.g. no valve connected)Vap valve current low43
AValve current is high (e.g. short circuit on valve out-
put)
Vap valve current high44
ANo contactor detectedVap contactor error45
AError detected via external signal inputVap external error46
AVap hardware errorVap electric error47
AFor Vapour Flow Switch and Bürkert indication,
maximum consecutive erroneous fillings reached.
VR consecutive filling48
EPossible fraud attempt. Contact Wayne.Illegal WIP incrementation49
BErrors from WIP used in Transaction ( -> F17.00 )Error on WIP in use50
AErrors from WIP not used in Transaction ( -> F17.01
)
Error on idle WIP51
ANo response from WIP used in TransactionNo response from WIP in use52
HZero fuel flow rate period detected during filling.Zero flow detection53
BBack pulses from WIP not used in Transaction ( ->
F16.03 )
Back pulses from idle WIP54
N/AN/AN/A55
BForward flow on WIP Not used in Transaction (indi-
cation of leakage) ( -> F19.14 )
Forward Flow on idle WIP56
N/AN/AN/A57
BWIP used in transaction didn’t respond on re-trans-
mission.
Comm failure with WIP in use58
AWIP didn’t respond to heart beat messageComm failure with WIP in idle59
WM048523 Rev 08 01/2019 181
10 Error Codes and Descriptions - IEC